Specification
Shipped With Each Unit: ProSoft Solutions DVD
Power Supply: 24 VDC nominal
Storage Temperature: -40°C to 80°C (-40°F to 176°F )
Power Supply: 10 to 36 VDC allowed
Power Supply: Positive, Negative, GND Terminals
Shock: IEC 60068-2-27; 15G @ 11ms, 3-Axis (Operational)
Shipped With Each Unit: J180 Power Connector
Operating Temperature: -25°C to 70°C (-13°F to 158°F )
Shipped With Each Unit: 5’ straight-through Ethernet cable
Shock: IEC 60068-2-27; 30G @ 18ms, 3-Axis (Non-Operational)
Current Load: 10 to 36 VDC @ 610 mA maximum
Current Load: 24 VDC nominal @ 300 mA
Relative Humidity: 5% to 95% RH with no condensation
Dimensions (H x W x D): 5.38 x 1.99 x 4.38 in 13.67 x 5.05 x 11.13 cm
Shipped With Each Unit: 2.5 mm screwdriver
Vibration: IEC 60068-2-6; 5G @ 10 to 150 Hz
Modbus TCP/IP Specifications
Supported clients: 10
Supported servers: MBAP = 5, Encapsulated = 5
Supported Modbus Function Codes: Read/Write Holding Registers (server only)
Supported Modbus Function Codes: Preset (Write) Single Holding Register
Supported Modbus Function Codes: Read Holding Registers
Supported Modbus Function Codes: Force (Write) Single Coil
Supported Modbus Function Codes: Read Input Registers
Supported Modbus Function Codes: Preset (Write) Multiple Holding Registers
Command List Polling: Each command can be individually enabled or disabled; write-only-on-data-change is available
Supported Modbus Function Codes: Mask Write Holding Register (server only)
Status Data: Error codes reported individually for each command
Command List: Up to 160 fully configurable client commands
Supported Modbus Function Codes: Force (Write) Multiple Coils
Command List: Up to 100 commands per client, each fully configurable for Function Code, slave address, register to/from addressing and word/bit count.
Supported Modbus Function Codes: Read Coil Status
Supported Modbus Function Codes: Read Input Status
PROFINET Specifications
Exchange Types: Cyclic Real-time (RT) and Acyclic Data
Driver Type: Class A Device
PROFINET I/O Data: 1440 bytes IN, 1440 bytes OUT
The Modbus TCP/IP to PROFINET device gateway offers bi-directional data transfer between a PROFINET Controller and Modbus TCP/IP networks. The Modbus TCP/IP driver uses multiple clients and servers for faster data throughput. The PROFINET driver operates as a PROFINET device (slave). The PLX32-MBTCP-PND gateways are stand-alone DIN-rail mounted units that provide two Ethernet ports for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.