Form Factor: Single Slot 1794 Backplane compatible
Locate in any slot of Backplane
BackPlane Current Load: 20 mA @ 5 VDC
External power supply: 12 VDC to 24 VDC
340 mA to 170 mA
Operating Temperature: 32° F to 131° F (0° C to 55° C)
Storage Temperature: -40° F to 185° F (-40° C to 85° C)
Configuration Serial port (PRT1): Mini-DIN
RS-232
Hardware handshaking
Application serial Port (PRT2): Mini-DIN
RS-232/422/485 jumper selectable
500 V optical isolation from backplane
Dimensions (with Module installed in Base): Height x Width x Depth
3 in. x 3.7 in. x 2.7 in.
94 mm x 94 mm x 69 mm
Shock: 30 g operational
50 g non-operational
Vibration: 5 g from 10 to 150 Hz
Relative Humidity: 5% to 95% (without condensation)
LED Indicators: Module status
Backplane transfer status
Application status
Serial activity and error LED status
Alarm: LED Indicators
Length: 2.7
Width: 3.7
Height: 3
Enclosure: Molded plastic,
Cable Entry: Serial Port
Application: Foreign Device Data Concentrator, Pipelines and Offshore Platforms, Food Processing, Mining, Pulp and Paper, SCADA Communications, Supports Enron Version of Modbus Protocol for Floating Point Data Transactions
Mounting: DIN-rail
_Temperature: 32° F to 131° F (0° C to 55° C)
Brand Name: PROSOFT
Sub Brand: MV94
Type: Communication Adapter
Special Features: Module acts as an input/output module between the Modbus network and the Rockwell Automation backplane. The data transfer from the FLEX processor is asynchronous from the actions on the Modbus network.
Standard: CUL US; CUL Canada; CE; Russian GOST-R; Korean KC;
Input: 24 VDC (19.2-31.2 VDC)
Output: 640 ma @ 5V
Functions: Module allows Rockwell Automation FLEX I/O processors to interface with Mitsubishi Heavy Industries equipment.
I/O Isolation: 500 V optical isolation from backplane
I/O Status Indication: LEDS
Interface: RS-232/422/485
The MVI69 Modbus Master/Slave Network Interface Module allows Rockwell Automation FLEX I/O processors to interface with Mitsubishi Heavy Industries equipment.