App Port (Ethernet modules): 10/100 Base-T Ethernet compatible interface
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as
specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-
per-second and less than or equal to 5 minutes duration
Shipped with Unit: RJ45 to DB-9M cables for each port
6-foot RS-232 configuration Cable
Storage Temp.: -40° F to 185° F (-40° C to 85° C)
Relative Humidity: 5 to 95% (without condensation)
LED Indicators: Power and Module Status
Application Status
CFG Port Activity
Ethernet Port Activity
Error Status
CFG Port (CFG): RJ45 (DB-9M with supplied cable)
RS-232 only
No hardware handshaking
Dimensions: Standard 1769 Single-slot module
Current Load: 800 mA max @ 5 VDC
Power supply distance rating of 2 (L43 and L45 installations on first 2 slots
of 1769 bus)
Operating Temp.: 32° F to 140° F (0° C to 60° C)
Display: 2 X 24 Alphanumeric; Clock And Date
Connection Cables: RJ45 to DB-9M
Interface: RS-232; RS-485; RS-422
Power Supply: 800 mA max@ 5 VDC
Mounting: DIN rail or panel mount
Length: 3.42"
Width: 2.22"
Height: 5.18"
Operating Temperature: 0 to 60°C (32 to 140°F)
Brand Name: PROSOFT
Sub Brand: MV69
Special Features: Single Slot Backplane Compatible, Recognized as Input/Output Module, Has Access to Processor Memory for Data Transfer Between Processor and Module, Ladder Logic is Used for Data Transfer, Current:800MILAMP at 5VDC, Port: Ethernet
Application: Food Processing, Petrochemical, Pulp and Paper, Automobile Manufacturing
Standard: EX Certificate; CB Safety; CE Mark; GOST-R; Korean KC Registration; Lloyd's Register; UL/cUL Class 1,DIV2; UL/cUL (Canada)
_Ethernet: 2;4
Communication: Modbus TCP/IP
Type: Communication Module
The inRAx Modbus TCP/IP Communication Module is designed to allow CompactLogix® /MicroLogix® processors to interface with other Modbus TCP/IP protocol-compatible devices, including not only Modicon® processors, but also a wide variety of other Client and server devices. The MVI69-MNET module is a single-slot solution that provides a powerful connection between Rockwell Automation® CompactLogix processors and Modbus TCP/IP network applications. The Modbus TCP/IP network applications include those networks hosted by Modicon Quantum processors, networks controlled by operator interface software applications, and the growing number of manufactured devices that support this protocol. The module acts as an input/output module between the Modbus TCP/IP network and the CompactLogix backplane. The data transfer from the processor is asynchronous from the actions on the Modbus TCP/IP network. A 5000 16-bit register data space in the module exchanges data between the processor and the Modbus TCP/IP network.