Shipped with Each Unit: Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
Power Supply: 24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade
Current Load: 500 mA max @ 32 VDC max
Operating Temperature: -4° F to 122° F (-20° C to 50° C)
Storage Temperature: -40° F to 185° F (-40° C to 85° C)
Relative Humidity: 5% to 95% (with no condensation )
Dimensions: Standard:
5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)
Extended:
5.20 in H x 2.73 in W x 4.52 in D
(13.2 cm x 6.934 cm x 11.48 cm)
LED Indicators: Power and Module Status
Application Status
Serial Port Activity
Serial Port Error Status
Configuration Serial Port: DB-9M RS-232 only
No hardware handshaking
Ethernet Port (Ethernet modules only): 10Base-T half duplex RJ45 Connector
Link and Activity LED indicators
Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as
specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-
per-second and less than or equal to 5 minutes duration
Application Ports: Modbus Plus Connector
Two DB9 Female Standard Modbus Plus connectors
Serial Port Isolation: 2500 V RMS port signal isolation per UL 1577
3000 VDC min. port to ground and port to logic power isolation
Sub Brand: 5000
Type: Stand-alone Gateway
Special Features: Ideal solution for applications where Remote I/O connectivity can be used to integrate DF1 Master/Slave devices into a system; Powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices).
Application: Manufacturing, Oil and Gas, Electrical Power and Food Processing.
Standard: ATEX, CE/EMC, Environmental, UL,GOST-R
Environmental Conditions: -20 to 50DEG C Operating, -40 to 85DEG C Storage, 5 to 95 Percent Humidity
Ethernet: 10Base-T
Interface: RS-232, RS-422, RS-485
Port: 2
Data Transfer Rate: 110 to 115
Configuration: Yes
Frequency Rating: 50 to 60
Connectivity: Serial
Protocol: DF1
Software Requirements: Drivers
Enclosure: Aluminum
Length: 4.52
Width: 2.07
Height: 5.2
Brand Name: PROSOFT
The ProLinx Rockwell Automation Remote I/O Adapter to DF1 Master/Slave Gateway creates a powerful connection between devices on a Remote I/O network and DF1 devices. This stand-alone DIN-rail mounted protocol gateway provides one Remote I/O port and up to four serial ports. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.