Specification
ProSoft Configuration Builder software included: View module database contents through serial connection to a desktop PC
Powerful network integration: Move data between dissimilar networks using two communication protocols on one gateway
Powerful network integration: Protocols share access to a common memory database to exchange data between networks
ProSoft Configuration Builder software included: Graphical drag-and-drop configuration tool for simple module configuration
PROFIBUS DP-V0 Slave protocol interface: Easy configuration - GSD file provided
Backed by ProSoft Technology: 20-year history of delivering high-quality, reliable solutions designed with you in mind
ProSoft Configuration Builder software included: Easy-to-use diagnostics window with menu-driven hardware and protocol diagnostics
PROFIBUS DP-V0 Slave protocol interface: Adds PROFIBUS DP Slave device monitoring and control to a IEC 60870-5-104 network
Backed by ProSoft Technology: Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer
IEC 60870-5-104 Server protocol Interface: Advanced Event Buffer control parameters allow better data bandwidth utilization
Backed by ProSoft Technology: Three-Year Warranty ensures reliability and protects against equipment failures
IEC 60870-5-104 Server protocol Interface: IEC 60870-5-104, Edition 2 Data Types and extended Cause of Transmission Support
IEC 60870-5-104 Server protocol Interface: Adds an IEC 60870-5-104 Server (Slave) Input and Output link to a PROFIBUS DP network
Powerful network integration: View diagnostic data for both networks from a single configuration/debug port
PROFIBUS DP-V0 Slave protocol interface: PROFIBUS Slave status may be stored in gateway database and retrieval by either protocol
PROFIBUS Specifications
Supported I/O length: 244 bytes Input data
Communication parameters: Baud Rate: 9.6 kbps to 12 Mbps
Configurable Parameters: PROFIBUS Node Address: 1 to 125
Configurable Parameters: Action on loss of PROFIBUS connection
Configurable Parameters: Comm Fail Timeout Multiplier
Configurable Parameters: Data byte swapping
Supported I/O length: 400 bytes total
Supported PROFIBUS DP features: Auto Baud Setting
Supported PROFIBUS DP features: PROFIBUS V0 Slave using Siemens SPC3 chipset
Supported I/O length: 244 bytes Output data
Supported PROFIBUS DP features: Freeze Mode
Configurable Parameters: Status Data location in Internal Database
Supported PROFIBUS DP features: Sync Mode
The IEC 60870-5-104 Server to PROFIBUS DP Slave Gateway creates a powerful connection between devices on an IEC 104 network and PROFIBUS DP Master devices. This stand-alone DIN-rail mounted gateway provides one PROFIBUS DP-V0 Slave DB9F port and one IEC 104 Server Ethernet port. The 104S gateway accepts and responds to commands from a network-connected Client (Master) and can also autonomously generate unsolicited messages for cyclic or event-driven data transmission. Firmware versions 3.00 and later support a wider range of IEC 60870-5-104 Edition 2 data types and Causes of Transmission than previously offered. The PROFIBUS Slave protocol supports the PROFIBUS DP-V0 implementation, providing powerful data transfer capability between the ProLinx gateway and a PROFIBUS DP Master. With relatively few options to adjust, the PROFIBUS DP Slave configuration is quick, simple, and easily accomplished using the provided ProSoft Configuration Builder software.