Specification
Acyclic Pass-Through Capability: Automatically generated DFBs enable advanced PROFIBUS DP-V1 acyclic messaging with minimal engineering and programming effort
New Application Communication Logic functions for use with Modicon M340 or Quantum PACs: Generates Unity Pro version 4.0 DFB logic and variable files from gateway configuration
Backed by ProSoft Technology: Free ProSoft Software tools tightly integrate with our hardware...a simple and quick, total solution to help you make our products fit your applications
New Application Communication Logic functions for use with Modicon M340 or Quantum PACs: Automates the creation of application communication logic
Acyclic Pass-Through Capability: Acyclic messaging allows a M340 or Quantum PAC to communicate directly with PROFIBUS DP slaves, to access special slave features, and to get extended slave diagnostics and process data
Backed by ProSoft Technology: Three-Year Warranty ensures reliability and protects against equipment failures
Backed by ProSoft Technology: 20-year history of delivering high-quality, reliable solutions designed with you in mind
New Application Communication Logic functions for use with Modicon M340 or Quantum PACs: Designed specifically to enable a Modicon M340 or QuantumPAC using Modbus TCP/IP to act as a PROFIBUS DP-V1 Master
New Application Communication Logic functions for use with Modicon M340 or Quantum PACs: Ease-of-use means faster deployment, less engineering effort, fewer programming errors
Backed by ProSoft Technology: Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer
Automating integration for Schneider Electric (SE) Modicon processors and maximizing ease-of-use are the hallmark design criteria behind the new ProLinx SE line of communication gateways. The first SE gateway, the 5204SE-MNET-PDPMV1 Modbus TCP/IP to PROFIBUS DP-V1 Master gateway, easily turns a Modicon M340 or a Quantum Programmable Automation Controller (PAC) into a PROFIBUS DP-V1 Master. The new Application Communication Logic functions built into ProSoft Configuration Builder (PCB) automatically generate all the Unity Pro data types, variables, and logic required for the M340 or Quantum to perform PROFIBUS DP-V1 cyclic and acyclic communication. PCB automatically generates customized export files based on the PROFIBUS DP network configuration for the gateway. These files import into Unity Pro version 4 software without modification, eliminating the need to write additional communications message logic. Automatically-generated Derived Function Block logic also provides advanced PROFIBUS DP-V1 acyclic message pass-through capability. Acyclic messaging allows an M340 or Quantum to request extended slave data and diagnostics, as well as access slave-specific special functions. Whenever the PROFIBUS DP network configuration changes, new logic files can be automatically created, exported, and imported into an existing project, reducing engineering demands and cutting deployment time. Changes to gateway configuration can be password-protected. The Modbus TCP/IP (MNET) driver can be used to interface many different protocols into the Schneider Electric Quantum family of processors as well other software solutions supporting the protocol. The MNET driver supports Client connections as well as Server connections. The PROFIBUS DP Master protocol driver (PDPMV1) supports complete Master specifications according to IEC 61158 on either a Mono-Master or Multi-Master network. The module supports the DPV1 specification.