Frequency Rating: 50 to 60
Configuration: Yes
Application: Manufacturing, Oil and Gas, Electrical Power and Food Processing.
Type: Stand-alone Gateway
Sub Brand: 5000
Brand Name: PROSOFT
Special Features: Ideal solution for applications where Modbus connectivity can be used to integrate an IEC 104 slave device into a system; Powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others).
Standard: ATEX, CE/EMC, Environmental, UL,GOST-R
Environmental Conditions: -20 to 50DEG C Operating, -40 to 85DEG C Storage, 5 to 95 Percent Humidity
Application Ports: Modbus Plus Connector
Two DB9 Female Standard Modbus Plus connectors
Ethernet Port (Ethernet modules only): 10Base-T half duplex RJ45 Connector
Link and Activity LED indicators
Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as
specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-
per-second and less than or equal to 5 minutes duration
Configuration Serial Port: DB-9M RS-232 only
No hardware handshaking
LED Indicators: Power and Module Status
Application Status
Serial Port Activity
Serial Port Error Status
Dimensions: Standard:
5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)
Extended:
5.20 in H x 2.73 in W x 4.52 in D
(13.2 cm x 6.934 cm x 11.48 cm)
Storage Temperature: -40° F to 185° F (-40° C to 85° C)
Operating Temperature: -4° F to 122° F (-20° C to 50° C)
Current Load: 500 mA max @ 32 VDC max
Power Supply: 24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade
Data Transfer Rate: 110 to 115
Port: 5
Interface: RS-232, RS-422, RS-485
Ethernet: 10Base-T
Shipped with Each Unit: Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
Serial Port Isolation: 2500 V RMS port signal isolation per UL 1577
3000 VDC min. port to ground and port to logic power isolation
Relative Humidity: 5% to 95% (with no condensation )
Connectivity: Serial
Protocol: SNTP, MCM, IEC 60870-5-104
Software Requirements: Drivers
Enclosure: Aluminum
Length: 4.52
Width: 2.07
Height: 5.2
The ProLinx family IEC60870-5-104 Server to Modbus Master/Slave communications module (5201-104S-MCM) creates a powerful connection between devices on a Modbus network and an IEC 104 client device. The module is a stand-alone DIN-rail mounted protocol gateway that provides one Ethernet port and up to four serial ports. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. The Modbus (MCM) protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.