Special Features: Ideal solution for applications where DNP 3.0 Master connectivity can be used to integrate a PROFIBUS DP Slave device into a system; Powerful module designed with Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices).
Shipped with Each Unit: Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
Serial Port Isolation: 2500 V RMS port signal isolation per UL 1577
3000 VDC min. port to ground and port to logic power isolation
Application Ports: Modbus Plus Connector
Two DB9 Female Standard Modbus Plus connectors
Ethernet Port (Ethernet modules only): 10Base-T half duplex RJ45 Connector
Link and Activity LED indicators
Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as
specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-
per-second and less than or equal to 5 minutes duration
Configuration Serial Port: DB-9M RS-232 only
No hardware handshaking
LED Indicators: Power and Module Status
Application Status
Serial Port Activity
Serial Port Error Status
Dimensions: Standard:
5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)
Extended:
5.20 in H x 2.73 in W x 4.52 in D
(13.2 cm x 6.934 cm x 11.48 cm)
Relative Humidity: 5% to 95% (with no condensation )
Storage Temperature: -40° F to 185° F (-40° C to 85° C)
Operating Temperature: -4° F to 122° F (-20° C to 50° C)
Current Load: 500 mA max @ 32 VDC max
Power Supply: 24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade
Environmental Conditions: -20 to 50DEG C Operating, -40 to 85DEG C Storage, 5 to 95 Percent Humidity
Height: 5.2
Width: 2.07
Length: 4.52
Enclosure: Aluminum
Software Requirements: Drivers
Protocol: PDPS, DNP, DNP 3.0
Connectivity: Serial
Frequency Rating: 50 to 60
Configuration: Yes
Data Transfer Rate: 110 to 115
Port: 2
Interface: RS-232, RS-422, RS-485
Ethernet: 10Base-T
Standard: ATEX, CE/EMC, Environmental, UL,GOST-R
Application: Manufacturing, Oil and Gas, Electrical Power and Food Processing.
Type: Stand-alone Gateway
Sub Brand: 5000
Brand Name: PROSOFT
The ProLinx DNP 3.0 Master to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a DNP 3.0 network and PROFIBUS DP master devices. This stand-alone DINrail mounted protocol gateway provides one serial port and PROFIBUS DB Slave port. The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.