Power Supply: 24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade
Current Load: 500 mA max @ 32 VDC max
Operating Temperature: -4° F to 122° F (-20° C to 50° C)
Storage Temperature: -40° F to 185° F (-40° C to 85° C)
Relative Humidity: 5% to 95% (with no condensation )
LED Indicators: Power and Module Status
Application Status
Serial Port Activity
Serial Port Error Status
Serial Port Isolation: 2500 V RMS port signal isolation per UL 1577
3000 VDC min. port to ground and port to logic power isolation
Shipped with Each Unit: Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
Dimensions: Standard:
5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)
Extended:
5.20 in H x 2.73 in W x 4.52 in D
(13.2 cm x 6.934 cm x 11.48 cm)
Configuration Serial Port: DB-9M RS-232 only
No hardware handshaking
Ethernet Port (Ethernet modules only): 10Base-T half duplex RJ45 Connector
Link and Activity LED indicators
Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as
specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-
per-second and less than or equal to 5 minutes duration
Application Ports: Modbus Plus Connector
Two DB9 Female Standard Modbus Plus connectors
Length: 4.52
Width: 2.07
Height: 5.2
Environmental Conditions: -20 to 50DEG C Operating, -40 to 85DEG C Storage, 5 to 95 Percent Humidity
Brand Name: PROSOFT
Sub Brand: 5000
Type: Stand-alone Gateway
Special Features: Fully configurable as either a Master or Slave utilizing the DF1 or Modbus Protocols; Can be used as a data concentrator; Work as a bridge between the two different protocols.
Application: Manufacturing, Oil and Gas, Electrical Power and Food Processing.
Standard: ATEX, CE/EMC, Environmental, UL,GOST-R
Ethernet: 10Base-T
Interface: RS-232, RS-422, RS-485
Port: 4
Data Transfer Rate: 110 to 115
Configuration: Yes
Frequency Rating: 50 to 60
Connectivity: Serial
Protocol: MCM, DF1
Software Requirements: Drivers
Enclosure: Aluminum
The ProLinx Modbus Master/Slave to DF1 Master/Slave Gateway creates a powerful connection between Modbus Master/Slave and DF1 Master/Slave networks and devices. This stand-alone DIN-rail mounted protocol gateway provides four serial ports, each individually configurable as a Modbus or DF1 Master or Slave. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments.