规格
Shipped With Each Unit: 2.5 mm screwdriver
Shock: IEC 60068-2-27; 15G @ 11ms, 3-Axis (Operational)
Shipped With Each Unit: DB9 to Screw Terminal Adapter
Power Supply: Positive, Negative, GND Terminals
Current Load: 10 to 36 VDC @ 610 mA maximum
Shipped With Each Unit: ProSoft Solutions DVD
Power Supply: 10 to 36 VDC allowed
Power Supply: 24 VDC nominal
LED Indicators: For configuration and protocol status errors
Shipped With Each Unit: 5’ straight-through Ethernet cable
Operating Temperature: -25°C to 70°C (-13°F to 158°F )
Shock: IEC 60068-2-27; 30G @ 18ms, 3-Axis (Non-Operational)
Dimensions (H x W x D): 5.38 x 1.99 x 4.38 in, 13.67 x 5.05 x 11.13 cm
Current Load: 24 VDC nominal @ 300 mA
Shipped With Each Unit: J180 Power Connector
Relative Humidity: 5% to 95% RH with no condensation
Vibration: IEC 60068-2-6; 5G @ 10 to 150 Hz
Operating Temperature: -40°C to 80°C (-40°F to 176°F )
Number of Serial Ports: 1
Modbus Serial Specifications
Supported Modbus Function Codes: Read Coil Status
Software configurable communication parameters: Parity: None, Even, Odd
Supported Modbus Function Codes: Read Holding Registers
Command List: Up to 100 commands, each fully configurable for Function Code, slave address, register to/from addressing and word/bit count.
Status Data: Error codes available on an individual command basis. In addition, a slave status list is maintained
RS Interface: RS232, RS422, and RS485
Software configurable communication parameters: RTS on/off delay: 0 to 65535 milliseconds
Polling of Command List: Configurable polling of command list, including continuous and on change of data
Supported Modbus Function Codes: Read Input Registers
Software configurable communication parameters: Data Size: 7 or 8 bits
Software configurable communication parameters: Stop bits: 1 or 2
Supported Modbus Function Codes: Force (Write) Multiple Coils
Software configurable communication parameters: Floating Point Data supported, support for Enron and Daniel
Software configurable communication parameters: Modbus Modes: RTU with CRC-16, ASCII mode with LRC error checking
Supported Modbus Function Codes: Read/Write Holding Registers (slave only)
Supported Modbus Function Codes: Preset (Write) Multiple Holding Registers
Supported Modbus Function Codes: Mask Write Holding Register (slave only)
Software configurable communication parameters: Baud rate: 110 baud to 115.2 kbps
Supported Modbus Function Codes: Force (Write) Single Coil
Supported Modbus Function Codes: Preset (Write) Single Holding Register
Supported Modbus Function Codes: Read Input Status
Node Address: 1 to 247 (software selectable)
PROFINET Specifications
Exchange Types: Cyclic Real-time (RT) and Acyclic Data
PROFINET I/O Data: 1440 bytes IN, 1440 bytes OUT
Driver Type: Class A Device